O

Orangeflare

Water Infrastructure AI

REVIEW

Wastewater design review with demo findings already loaded

Upload drawing packages, classify pages, extract tags, and review findings against standards and deterministic engineering rules. This demo is preloaded from the Fulshear package.

Total findings

73

Critical

0

High

5

Medium+

34

Upload package

Drag and drop a PDF here

Demo mode is showing precomputed Fulshear results.

Review status

Pipeline progress

Complete
Sheets classified100%
Tags extracted100%
Standards checked100%
Findings published100%

Results

73 review findings

Sorted by severity · asc

highN+1 redundancy not evident for influent pumpprocess34rules70%
highN+1 redundancy not evident for ras pumpprocess34rules70%
highN+1 redundancy not evident for blowerprocess37rules70%
highN+1 redundancy not evident for chlorine feed pumpprocess34rules70%
highN+1 redundancy not evident for polymer feed pumpprocess34rules70%
mediumInstrument AIT-1111 is not connected in extracted loop graphinstrumentation34loop70%
mediumInstrument AIT-1112 is not connected in extracted loop graphinstrumentation34loop70%
mediumInstrument AIT-1311 is not connected in extracted loop graphinstrumentation34loop70%
mediumInstrument AIT-1312 is not connected in extracted loop graphinstrumentation34loop70%
mediumInstrument AIT-1313 is not connected in extracted loop graphinstrumentation34loop70%
mediumInstrument AIT-1314 is not connected in extracted loop graphinstrumentation34loop70%
mediumInstrument AIT-1321 is not connected in extracted loop graphinstrumentation34loop70%
mediumInstrument AIT-1322 is not connected in extracted loop graphinstrumentation34loop70%
mediumInstrument AIT-1323 is not connected in extracted loop graphinstrumentation34loop70%
mediumInstrument AIT-1324 is not connected in extracted loop graphinstrumentation34loop70%
mediumInstrumentation completeness should be verifiedinstrumentation5compliance70%
mediumInstrumentation completeness should be verifiedinstrumentation23compliance70%
mediumInstrumentation completeness should be verifiedinstrumentation37compliance70%
mediumInstrumentation completeness should be verifiedinstrumentation40compliance70%
mediumInstrumentation completeness should be verifiedinstrumentation45compliance70%
mediumInstrumentation completeness should be verifiedinstrumentation47compliance70%
mediumInstrumentation completeness should be verifiedinstrumentation51compliance70%
mediumInstrumentation completeness should be verifiedinstrumentation53compliance70%
mediumInstrumentation completeness should be verifiedinstrumentation57compliance70%
mediumInstrumentation completeness should be verifiedinstrumentation58compliance70%
mediumInstrumentation completeness should be verifiedinstrumentation60compliance70%
mediumNo valve tags extracted from P&IDprocess5rules70%
mediumNo valve tags extracted from P&IDprocess23rules70%
mediumNo valve tags extracted from P&IDprocess40rules70%
mediumNo valve tags extracted from P&IDprocess45rules70%
mediumNo valve tags extracted from P&IDprocess47rules70%
mediumNo valve tags extracted from P&IDprocess51rules70%
mediumNo valve tags extracted from P&IDprocess53rules70%
mediumNo valve tags extracted from P&IDprocess58rules70%
lowNo extracted flow-control relationship for FM-1122process34loop70%
lowNo extracted flow-control relationship for LIT-1111process34loop70%
lowNo extracted flow-control relationship for LIT-1311process34loop70%
lowNo extracted flow-control relationship for LIT-1312process34loop70%
lowNo extracted flow-control relationship for LIT-1313process34loop70%
lowNo extracted flow-control relationship for LIT-1314process34loop70%
lowNo extracted flow-control relationship for MXR-1111process34loop70%
lowNo extracted flow-control relationship for MXR-1112process34loop70%
lowNo extracted flow-control relationship for P-1121process34loop70%
lowNo extracted flow-control relationship for P-1122process34loop70%
lowNo extracted flow-control relationship for PV-1121process34loop70%
lowNo extracted flow-control relationship for PV-1122process34loop70%
lowNo extracted flow-control relationship for PV-1123process34loop70%
lowNo extracted flow-control relationship for PV-1124process34loop70%
lowNo extracted flow-control relationship for PV-1211process34loop70%
lowNo extracted flow-control relationship for SG-1112process34loop70%
lowNo extracted flow-control relationship for SG-1113process34loop70%
lowNo extracted flow-control relationship for SG-1114process34loop70%
lowNo extracted flow-control relationship for BFV-2111process37loop70%
lowNo extracted flow-control relationship for BFV-2112process37loop70%
lowNo extracted flow-control relationship for BFV-2113process37loop70%
lowNo extracted flow-control relationship for BFV-1101process57loop70%
lowNo extracted flow-control relationship for BFV-1201process57loop70%
lowNo extracted flow-control relationship for DCTR-1101process57loop70%
lowNo extracted flow-control relationship for DCTR-1201process57loop70%
lowNo extracted flow-control relationship for DO-1201process57loop70%
lowNo extracted flow-control relationship for FE-1102process57loop70%
lowNo extracted flow-control relationship for FE-1201process57loop70%
lowNo extracted flow-control relationship for FM-3101process57loop70%
lowNo extracted flow-control relationship for P-2101process57loop70%
lowNo extracted flow-control relationship for P-2201process57loop70%
lowNo extracted flow-control relationship for PV-1101process57loop70%
lowNo extracted flow-control relationship for PV-1201process57loop70%
lowNo extracted flow-control relationship for PV-2101process57loop70%
lowNo extracted flow-control relationship for PV-2201process57loop70%
lowNo extracted flow-control relationship for P-5101process60loop70%
lowNo extracted flow-control relationship for P-5201process60loop70%
lowNo extracted flow-control relationship for PV-5101process60loop70%
lowNo extracted flow-control relationship for PV-5201process60loop70%